Confidential, the whole present document is the sole property of Maestro Wireless Solution Ltd.
85
ANALOGUE INPUT AI
Service Id
Operation Type
Argument and Explanation
1 to 1
TP
1 to 3 (Trigger type: higher than HL, lower than LL, or both)
TH
1 to 255 (threshold tp trigger unit in 0.1 second)
HL
0 to 5000 (High Limit unit mV)
LL
0 to 5000 (Low Limit unit mV )
TR
0 to 50 (CS to trigger, 0 to cancel)
SOCKET COMMUNICATIONSC
Service Id
Operation Type
Argument and Explanation
1 to 10
TO
1 to10 (Host ID)
BD
0-3 (body/content id, 0 to cancel)
SN
(additional email content)
(variable : %CTn counter value
%IP input port value
%TMn countdown timer value
%AI Analogue input values)